Your are here at :

PRODUCTS

CONTACT US

LSZH Cable Standard H05Z1Z1-F: Fire Safety Requirements for Commercial Buildings

H05Z1Z1-F Technical Profile & Fire Safety Role

H05Z1Z1-F is a harmonized flexible cable rated at 300/500V, featuring fine-stranded annealed copper conductors (class 5 per EN 60228 [1]), thermosetting LSZH [2]insulation, and an LSZH outer sheath. Designed for dynamic or fixed indoor installations in commercial buildings, it eliminates toxic halogen acid gas emission during thermal breakdown. Core compliance mandates IEC 60332-1-2 (single-wire vertical flame propagation [3]), IEC 61034-2 (smoke density 60%\geq 60\% light transmittance), and IEC 60754-2 (halogen acid gas conductivity <10μS/mm< 10\,\mu\text{S/mm} and pH4.3\text{pH} \ge 4.3). It balances mechanical flexibility with stringent life-safety evacuation criteria in high-occupancy spaces.

Technical & Compliance Parameter Matrix

ParameterSpecification StandardTechnical Value / Rating
Rated Voltage (U0/UU_0/U)EN 50525-3-11 / HD 21.14300 / 500 V
Test Voltage (AC)EN 503952.0 kV (50 Hz, 15 min)
Conductor ClassEN 60228Class 5 (flexible annealed copper)
Operating TemperatureEN 50525-3-11 15C-15^\circ\text{C} to +70C+70^\circ\text{C} (flexing/fixed)
Flame RetardancyIEC 60332-1-2Pass (single insulated cable/conductor)
Smoke DensityIEC 61034-2Light transmittance It60%I_t \ge 60\%
Halogen-Free StatusIEC 60754-1 / -2HCl+HBr<0.5%\text{HCl}+\text{HBr} < 0.5\%, pH4.3\text{pH} \ge 4.3, conductivity <10μS/mm< 10\,\mu\text{S/mm}
Minimum Bend RadiusEN 50565-16×overall diameter (fixed/flexible combined)6 \times \text{overall diameter (fixed/flexible combined)}

Material Composition & Core Architecture

  • Conductor: Flexible annealed copper (IEC 60228 Class 5) providing high fatigue resistance under repeated mechanical stress.
  • Insulation: Cross-linked or thermoplastic Low Smoke Zero Halogen compound preventing corrosive acid generation.
  • Sheath: Type Z1 thermoplastic LSZH compound offering low toxic fume emission and moderate abrasion resistance.
  • Identification: Standard color-coding or numbered cores with optional green/yellow protective earth.

Commercial Building Application & Deployment Rules

  • Primary Scenarios: Public assembly halls, HVAC control loops, recessed lighting feeds, and temporary power drops where escape routes require clear visibility.
  • Installation Constraints: Unsuitable for direct burial, outdoor exposure without UV-stabilized conduit, or high-mechanical-impact industrial trays without armor.
  • Compatibility Check: Must terminate with certified IP-rated or barrier glands maintaining enclosure integrity under thermal stress.

CJDL CABLE Engineering Insight

While H05Z1Z1-F serves general indoor building circuits, our engineering team recommends specifying halogen-free flexible cables for escape-route and high-occupancy feeders, where smoke density and gas acidity directly affect evacuation safety. All CJDL CABLE LSZH flexible cables are manufactured and routinely tested to IEC 60332-1-2, IEC 61034-2 and IEC 60754-2. In commercial building projects supplied by CJDL CABLE, compliant LSZH construction has helped maintain smoke clarity during emergency scenarios while meeting 300/500V installation requirements.

References

[1] Wikipedia. IEC 60228 [EB/OL]. 2026-01-01. [2] Wikipedia. Low smoke zero halogen [EB/OL]. 2026-01-01. [3] Wikipedia. IEC 60332 [EB/OL]. 2026-01-01.